Electricity and water do not form a happy partnership, do they?
Drying Out Electrical Equipment Electricity and water do not form a happy partnership and so it is often necessary to. Read more
View ArticleFew good tips for low voltage switchgear maintenance and care
Low voltage switchgear The low voltage switchgear involves many devices like power circuit breakers, MCBs, aux. relays, CTs, VTs etc.. Read more
View ArticleUsing Megger tester for these 3 types of insulation resistance tests
Types of insulation resistance tests You know that good insulation has high resistance and poor insulation relatively low resistance. The. Read more
View ArticleGuidelines for high potential (Hi-Pot) DC testing of medium voltage cables
High potential “Hi-Pot” DC testing This technical article provides general guidelines for high potential “Hi-Pot” DC testing of MV power. Read more
View ArticlePerforming power factor test on dry-type transformer during commissioning
Power factor test The power factor test is a maintenance test used to determine the insulation system dielectric power loss. Read more
View Article5 components of current drawn by the DC voltage testing of insulation
When DC voltage is applied to an insulation, the electric field stress gives rise to current conduction and electrical polarization. Consider an elementary circuit as shown in Figure 1 below,... Read...
View Article7 Methods To Avoid Insulator Flashovers
Contamination caused insulator flashovers produce frequent outages in severely contaminated areas. Lines closer to the ocean are in more danger of becoming contaminated. Several countermeasures have...
View ArticleWhere do electrical faults occur the most?
A fault is not a natural occurrence. It is an unplanned event which occurs unexpectedly. Electrical faults in an electrical installation or piece of equipment may be caused by: Negligence –... Read...
View ArticleBetter understanding of transformer failures and maintenance necessity
Generally speaking, the transformer requires less care compared to other electrical equipment. But, as I already stated in some of the earlier technical articles, transformer failures can cause a...
View ArticleWhat would be the best conductor material for electrical wires and cables
The conductivity of copper is 65% higher than that of aluminium which means that the conductor size of similarly rated cables is proportionately smaller. Correspondingly less expense is then...
View ArticleElectricity and water do not form a happy partnership, do they?
Electricity and water do not form a happy partnership and so it is often necessary to “dry out” insulation. This may be done to remove surface moisture or perhaps to... Read moreThe post Electricity...
View ArticleFew good tips for low voltage switchgear maintenance and care
The low voltage switchgear involves many devices like power circuit breakers, MCBs, aux. relays, CTs, VTs etc. and of course at the end – enclosures (indoor or outdoor type). The frequency... Read...
View ArticleUsing Megger tester for these 3 types of insulation resistance tests
You know that good insulation has high resistance and poor insulation relatively low resistance. The actual resistance values can be higher or lower, depending upon such factors as the temperature......
View ArticleGuidelines for high potential (Hi-Pot) DC testing of medium voltage cables
This technical article provides general guidelines for high potential “Hi-Pot” DC testing of MV power cables. All tests made following cable installation and during the warranty period must be...
View ArticlePerforming power factor test on dry-type transformer during commissioning
The power factor test is a maintenance test used to determine the insulation system dielectric power loss by measuring the power angle between an applied AC voltage and the resultant... Read moreThe...
View ArticleWhy substation equipment fails and why it’s wise to think of that much before...
This technical article will try to shed some light on why and how electrical equipment fails and what’s happening before and during the failure of particular substation equipment like switchgear,......
View ArticleEight criteria you should consider when choosing the right MV/LV transformer...
Although there are few common-sense rules that every electrical engineer follow when choosing the transformer type, it’s always a good idea to name the most important of them. This technical... Read...
View ArticleElectrical insulation testing – Often underestimated until things go really bad
Due to mechanical damage, vibrations, (excessive) heat/cold, moisture/humidity, chemical influences and interactions and aging pinholes, cracks causes moisture and foreign matter to penetrate the...
View ArticleRecommendations for the successful erection of medium voltage switchgear
Electrical engineers working on project execution know that switchgear erection brings many challenges, no matter the voltage level. The switchgear cannot always be assembled in the factory and...
View ArticleThe most common failure modes of electrical equipment in distribution systems
Each piece of electrical equipment on a distribution system has a probability of failing. When first installed, a piece of equipment can fail due to poor manufacturing, damage during shipping,... Read...
View Article