Quantcast
Channel: insulation Archives | EEP - Electrical Engineering Portal
Browsing all 46 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

Inspection of electrical installations in home (2)

Inspection of electrical installations in home Continued from part I – Inspection of electrical installations in home (part 1) Is a Periodic Inspection Needed?Every installation deteriorates with use...

View Article


Image may be NSFW.
Clik here to view.

Measurement of insulation resistance (IR) – Part 2

Fluke insulation resistance tester up to 10kV - Allows testing of high voltage systems such as control gears, engines, generators and cables. It can be adjusted to all testing voltages that are...

View Article


Image may be NSFW.
Clik here to view.

Meggering (insulation resistance testing) of dry-type power transformer

MEGGER - Insulation resistance test deviceThe insulation resistance test (meggering) is of value for future comparison and also for determining if the transformer is to be subjected to the applied...

View Article

Image may be NSFW.
Clik here to view.

Fundamental Concepts of Insulation Testing

Fundamental concepts of insulation testing (on photo Digital Surge/ HiPot / Resistance Tester on site) IntroductionProbably 80% of all testing performed in electrical power systems is related to the...

View Article

Image may be NSFW.
Clik here to view.

Basics of 3-phase Induction Motor (part 2)

Basics of 3-phase Induction Motor (part 2) Continued from first part – Basics of 3-phase Induction Motor (part 1)For the purpose of standardization, the preferred rated voltages of three phase...

View Article


Image may be NSFW.
Clik here to view.

Right Choice of Dry Type or Liquid-Filled Transformer

Right Choice of Dry Type or Liquid-Filled Transformer (on photo Dynapower Corporation transformers)Content1. Two Types of Transformers 2. Cooling and insulating system 3. Losses 4. Operating Life of...

View Article

Image may be NSFW.
Clik here to view.

Definition of Basic Insulation Level (BIL)

Definition of Basic Insulation Level (BIL) - photo by bob1217 @ FlickrIntroduction to BILInsulation levels are designed to withstand surge voltages, rather than only normal operating voltages. Since...

View Article

Image may be NSFW.
Clik here to view.

Inspection and Test Procedures for Metal-Enclosed Busways

Inspection and Test Procedures for Metal-Enclosed BuswaysContentVisual and Mechanical InspectionElectrical TestsTest ValuesTest Values – Visual and MechanicalTest Values – ElectricalTables:TABLE 100.12...

View Article


Image may be NSFW.
Clik here to view.

Differences Between Earthed and Unearthed Cables

Differences Between Earthed and Unearthed CablesIntroductionIn HT electrical distribution, the system can be earthed or unearthed.The selection of unearthed or earthed cable depends on distribution...

View Article


Image may be NSFW.
Clik here to view.

Selection of Induction Motors for Industrial Applications (part 2)

Selection of Induction Motors for Industrial Applications (part 2) - photo by TCD Systems Continued from first part: Selection of Induction Motors for Industrial Applications (part 1) Design...

View Article

Image may be NSFW.
Clik here to view.

Electrical Preventive Maintenance of Air Circuit Breakers

Electrical Preventive Maintenance of Air Circuit BreakersRecommended minimum practice for preventive maintenanceInsulationRemove and clean interphase barriers. Clean all insulating materials with...

View Article

Image may be NSFW.
Clik here to view.

Why is Continuous On-line Monitoring of Partial Discharge in the Switchgear...

Why is Continuous On-line Monitoring Partial Discharge in the Switchgear Necessary? (on photo: 11kV voltage transfromer spout failure in progress – Located by Partial Discharge survey; by...

View Article

Image may be NSFW.
Clik here to view.

4 Essential Qualities Of Electrical Protection

4 Essential Qualities Of Electrical Protection (on photo protection relat panel by powersystemsmasters.com)Fundamental Protection RequirementsIn generating stations, all electrical circuits and...

View Article


Image may be NSFW.
Clik here to view.

Degradation of Insulation in Switchgear (What’s Really Happening)

Degradation of Insulation in Switchgear (why you should take it seriously); photo credit: Schneider ElectricPartial Discharge (PD)Electrical insulation is subjected to electrical and mechanical stress,...

View Article

Image may be NSFW.
Clik here to view.

6 Transformer Types You Can See In Commercial Installations

6 Transformer Types You Can See In Commercial Buildings (photo credit: iml.bg)Transformer Types and their CharacteristicsTransformers in commercial installations are normally used to change a voltage...

View Article


Image may be NSFW.
Clik here to view.

5 Components of Current Drawn by the DC Voltage Testing of Insulation

Current drawn by the insulationWhen DC voltage is applied to an insulation, the electric field stress gives rise to current conduction and electrical polarization. Consider an elementary circuit as...

View Article

Image may be NSFW.
Clik here to view.

7 Methods To Avoid Insulator Flashovers

Transmission Line Insulator FlashoversContamination caused insulator flashovers produce frequent outages in severely contaminated areas. Lines closer to the ocean are in more danger of becoming...

View Article


Image may be NSFW.
Clik here to view.

Where Do Electrical Faults Occur The Most?

Causes of electrical faults // A fault is not a natural occurrence. It is an unplanned event which occurs unexpectedly. Electrical faults in an electrical installation or piece of equipment may be...

View Article

Image may be NSFW.
Clik here to view.

Better understanding of transformer failures and maintenance necessity

Transformer failures Generally speaking, the transformer requires less care compared to other electrical equipment. But, as I already stated in some of the earlier technical articles, transformer...

View Article

Image may be NSFW.
Clik here to view.

What Would Be The Best Conductor Material for Electrical Cables

Al or Cu conductor… The conductivity of copper is 65% higher than that of aluminium which means that the conductor size of similarly rated cables is proportionately smaller. Correspondingly less...

View Article
Browsing all 46 articles